Verification of the performance of the
sanitation procedure is as important as the actual application. The methods
that are going to be used for such verification needs to be user friendly and
rapid resulting to apply the corrective actions promptly. Additionally, these
methods should also be reliable besides their fast resulting. ATP
bioluminescence method is recommended to be a solution for such procedures for
many years. In this present study, our
aim was to evaluate the performance of ATP bioluminescence method by comparison
with golden standard classical cultural method. For this we performed parallel
testing on surfaces which were experimentally contaminated with different types
of microorganisms. The results showed that ATP bioluminescence gives more
reliable results in surfaces which do not have any physical dirt and are
contaminated with high level of microorganisms. The most reliable results were
obtained from Salmonella contaminated
surfaces.
Hygiene monitoring Poultry hygiene ATP bioluminescense Food hygiene Rapid hygiene monitoring
Primary Language | English |
---|---|
Subjects | Food Engineering |
Journal Section | Research Articles |
Authors | |
Publication Date | April 1, 2019 |
Submission Date | March 8, 2018 |
Published in Issue | Year 2019 |
Diamond Open Access refers to a scholarly publication model in which journals and platforms do not charge fees to either authors or readers.
Open Access Statement:This is an open access journal which means that all content is freely available without charge to the user or his/her institution. Users are allowed to read, download, copy, distribute, print, search, or link to the full texts of the articles, or use them for any other lawful purpose, without asking prior permission from the publisher or the author. This is in accordance with the BOAI definition of open access.
Archiving Policy:
Archiving is done according to ULAKBİM "DergiPark" publication policy (LOCKSS).